Extra Flex R9 PETP-PUR

Code
Formation
Ext.Diam mm
CU-weight kg/km
R9H16RXX
4x(4x0.50)
12.4
76

APPLICATION :
Special cable for "signal-service" for robots, Dynamic applications.
TECHNICAL CHARACTERISTICS :
Service Voltage :
250V
Test Voltage :

1500V
Insulation Resistance :
>/= 100 Mohm x km (at 20oC)
Capacitance :
abt. 85 nF/km at 20oC
Temperature :
service from 0oC to +80oC, storage from -40oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
PETP polyester terephtalate
Conductors Identification :
different colours
Taping :
special tape
Jacket :
special PUR compound abrasion-freeblack colour RAL 9005
Min. Bending Radius :
90 mm
Translation Speed :
180m/min.
Max. Acceleration :
5m/s2
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20-35 for flame resistance VDE 0472-803-B for ASTM2 oil resistance VDE 0472-815 halogen-free version.